It is advisable to check the nitrogen
precharge with the appropriate instrument every 6 months using the
appropriate VGU instrument.
The control must be done with the
machine or plant stopped and at room temperature. In the case in which the
value of the preload has dropped below 10% of the initial value, it is
necessary to intervene to restore it. If the preload is close to zero or
zero, it is very likely that the inner bag will be damaged or broken. In this
case, contact us for suggestions on how to proceed or agree to send the
accumulator to us where, after a check, we will send an estimate to restore
the damaged battery or replace it with a new one. If you have the equipment
and / or experience we can send you the original spare parts to proceed with
the review of the accumulator. for the disassembly of the accumulator it is
advisable to install an element on the circuit that separates it from it.
This is the purpose of the special DI series safety blocks.
Important:
It is essential to use dry nitrogen in
a cylinder equipped with a reducer. The use of other gases such as air or
oxygen is strictly prohibited due to the risk of explosion
From 2019 COMER is officially the Parker/Olaer Accumulators
service center. Comer has all the appropriate equipment and large spare parts
warehouse to perform checks on the preloads, internal bag replacements and
interventions in general on the whole range of accumulators in production both
Parker and Olaer.