The FT291 isolator needle valves (90 degree angle) are normally used to protect
the pressure gauge since they have the double function of dampening
pressure surge during opening and of isolating the pressure gauge entirely.
Pressed in high-resistance steel, protected by an accurate treatment,
subjected to strict tests, they ensure reliability and long life.
A rotating swivel nut allows for accurate pressure gauge orientation.
The sealing, standard supplied, and inserted in the nut, prevents any
drawing between the connection and the gauge.
For pressure gauge with taper threads, it will be necessary to use copper
washers FT 1201 to be requested
separately. Suitable for pressure up to 400 bar and temperature
from -20° to +100° they can be panel mounted by use of log nut (G),
supplied on request